For requests for repairs, dispatch of engineers, or quotation Click here to contact us

DCV HOW TO OPEN


Diaphragm Installation Procedure

1 Check the Diaphragm Valve Internal
Remove bolt (M19x8) on top cover of the diaphragm valve. Loosen bolts evenly together.
Remove top cover and check the following:
1-1 Edge of the diaphragm is correctly inserted in groove of casing
1-2 Condition of the diaphragm (are there cracks, tears, etc?)
1-3 Corrosion or cracks in the diaphragm casing
1-4 Clear any foreign matter in the diaphragm casing
1-5 Check that shaft moves up and down smoothly.